0.1PPM Infrared Carbon And Sulphur Analyser For Casting Industry Raw Material Testing
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Details
| Measurement Accuracy | 0.1PPM | Detection Method | Infrared Absorption Method |
|---|---|---|---|
| Analysis Method | Combustion And Absorption Method | Power Supply | 220V, 50Hz |
| Measurement Range | 0.000001% - 100% | Analysis Time | Less Than 60 Seconds |
| Weight | 50kg | ||
| Highlight | 0.1PPM carbon and sulphur analyser,50Hz carbon and sulphur analyser,0.1PPM carbon and sulfur analyzer |
||
You can tick the products you need and communicate with us in the message board.
| Measurement range | Cω(C): 0.000001%~99.999999% (≤10% or ≥10% expandable to 99.9999%)Sω(S): 0.000001%~99.999999%(≤10% or ≥10% expandable to 99.9999%) | |
|---|---|---|
| Analytical precision | C:≤RSD0.5%. S:RSD≤1.0% | |
| Sensitivity | 0.1PPM | |
| Analysis time | 25-60s (normally 35s) | |
| Analytic error | meet standard: JJG395-2016 (C: ISO9556, S: ISO4935) | |
| Oscillation frequency | 20MHz | |
| Burning power | 2.5KVA—7.5KVA( adjustable) | |
| Working environment | Indoor temperature: 10℃~30℃Relative humidity: 75% | |
| Voltage | AC220V±5%, Frequency:50H±2% |
Product Description
High-Frequency Infrared Carbon And Sulfur Analyzer QR-9000S For Casting Industry Raw Material Testing
The QR-9000S High-Frequency Infrared Carbon and Sulfur Analyzer is an advanced analytical instrument widely used for the precise measurement of carbon and sulfur content in raw materials used in the casting industry. With a remarkable precision (C: ≤ RSD 0.5%) and high sensitivity (0.1 PPM), this analyzer ensures that foundry materials such as metal alloys, sand, and other components meet the highest standards for quality and performance. Its broad carbon measurement range (0.000001% to 99.999999%) allows it to measure both low and high concentrations of carbon, making it an essential tool for foundries looking to optimize their production processes.
Key Features and Benefits
High Precision and Sensitivity: The QR-9000S delivers exceptional precision with carbon analysis accuracy of ≤ RSD 0.5% and sulfur sensitivity of 0.1 PPM. This level of accuracy is crucial for foundries where the carbon content significantly influences the properties of the metal, including strength, hardness, and ductility.
Wide Carbon Measurement Range: The analyzer’s carbon measurement range of 0.000001% to 99.999999% ensures that it can be used for a variety of raw materials in the casting industry, from high-carbon alloys to low-carbon base metals, providing a versatile solution for different types of castings.
Rapid Analysis Time: With an analysis time of just 25-60 seconds, the QR-9000S offers quick results, making it ideal for high-volume testing in casting operations. The typical analysis time of 35 seconds enables continuous quality control without slowing down production.
Advanced Infrared Detection System: The QR-9000S features a platinum infrared light source and high-precision pyroelectric infrared detectors that ensure stable, reliable, and accurate results even under the challenging conditions of a foundry environment.
User-Friendly Software Interface: The analyzer is equipped with an intuitive software interface that supports both English and Chinese, allowing easy operation. The software also supports real-time data integration, system diagnostics, and automatic adjustments, reducing the likelihood of human error.
Cost-Effective and Durable: Designed with a high-frequency combustion system and gold-plated analysis cells, the QR-9000S is built for durability, providing long-term reliability with minimal maintenance, which makes it a cost-effective choice for foundries.
Applications in Casting Industry Raw Material Testing
The QR-9000S High-Frequency Infrared Carbon and Sulfur Analyzer is essential for quality control in the casting industry, particularly for testing the raw materials used to produce metal castings. Foundries work with a variety of metals and alloys, where carbon and sulfur content directly impact the properties of the final casting, such as strength, hardness, and workability.
Alloy Quality Control: Carbon and sulfur content must be carefully monitored in alloys used for casting. Excess carbon can result in brittle castings, while sulfur can cause defects such as hot shortness, which weakens the metal.
Raw Material Testing: The QR-9000S ensures that raw materials such as metals, scrap, and alloying elements meet the required carbon and sulfur specifications before they are used in casting processes.
Process Optimization: By accurately measuring carbon and sulfur levels at various stages of the casting process, foundries can optimize their operations, improving the quality and consistency of the final cast products.
Final Product Inspection: The analyzer is also used for quality control of the final casting, ensuring that the carbon and sulfur content is within the desired range for mechanical properties and performance in end applications.
Advantages
Enhanced Quality Control: By accurately measuring carbon and sulfur content in raw materials and alloys, the QR-9000S ensures that castings meet stringent industry standards, resulting in fewer defects and higher-quality products.
Fast Testing and Results: The rapid analysis time supports high-throughput testing, ensuring that production lines remain efficient without sacrificing accuracy or reliability.
Cost-Efficiency: With minimal maintenance requirements and robust design, the QR-9000S offers a cost-effective solution for foundries looking to improve their quality control processes.
Reliable and Consistent Performance: The infrared detection system ensures stable and reproducible results, even in the demanding environment of a foundry, where environmental conditions can fluctuate.
Technical Specifications
Specification Value
Measurement Element C and S
Measurement Range C: 0.000001% – 99.999999% (expandable)
S: 0.000001% – 99.999999% (expandable)
Analytical Precision C: ≤ RSD 0.5%, S: ≤ RSD 1.0%
Sensitivity 0.1 PPM
Analysis Time 25-60s (typically 35s)
Oscillation Frequency 20 MHz
Burning Power 2.5 KVA – 7.5 KVA (adjustable)
Working Environment 10°C – 30°C, 75% relative humidity
Voltage AC220V ± 5%, Frequency: 50Hz ± 2%
Communication USB data exchange technology
Conclusion
The QR-9000S High-Frequency Infrared Carbon and Sulfur Analyzer is an indispensable tool for raw material testing in the casting industry. Its precision, fast analysis, and versatility make it ideal for quality control in foundries, ensuring that the carbon and sulfur content in alloys and metals meet strict industry specifications. By improving testing efficiency and accuracy, it helps foundries produce high-quality castings, reduce defects, and optimize their production processes.