All Products
-
Carbon Sulfur Analyzer
-
Spectrometer Machine
-
Sand Strength Testing Machine
-
Green Sand Testing Equipment
-
Coated Sand Performance Tester
-
Sand Air Permeability Tester
-
Gas Evolution Tester
-
Surface Tester
-
Sand Rammer
-
Sand Mixer
-
Sand Washing Machine
-
Sand Sieving Machine
-
Methylene Blue Absorption Tester
-
Shatter Index Tester
-
Sand Testing Equipments
Contact Person :
Treeing Sui
Phone Number :
+86 18921185109
220V Infrared Carbon And Sulfur Analyzer For Video Packaging Materials Inspection
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Details
| Storage Temperature | -20-60℃ | Operating Temperature | 10-40℃ |
|---|---|---|---|
| Detection Method | Infrared Absorption Method | Analysis Time | Less Than 60 Seconds |
| Dimensions | 600mm X 400mm X 400mm | Interface | RS232/USB |
| Power Supply | AC 220V/50Hz | Measurement Range | 0.001%-99.999% |
| Sample Type | Solid, Liquid, Gas | ||
| Highlight | infrared carbon and sulfur analyzer,infrared carbon sulfur analyzer,usb carbon sulfur analyzer |
||
You can tick the products you need and communicate with us in the message board.
| Measurement range | Cω(C): 0.000001%~99.999999% (≤10% or ≥10% expandable to 99.9999%)Sω(S): 0.000001%~99.999999%(≤10% or ≥10% expandable to 99.9999%) | |
|---|---|---|
| Analytical precision | C:≤RSD0.5%. S:RSD≤1.0% | |
| Sensitivity | 0.1PPM | |
| Analysis time | 25-60s (normally 35s) | |
| Analytic error | meet standard: JJG395-2016 (C: ISO9556, S: ISO4935) | |
| Oscillation frequency | 20MHz | |
| Burning power | 2.5KVA—7.5KVA( adjustable) | |
| Working environment | Indoor temperature: 10℃~30℃Relative humidity: 75% | |
| Voltage | AC220V±5%, Frequency:50H±2% |
Product Description
The QR-9000S High-Frequency Infrared Carbon and Sulfur Analyzer is an advanced, high-precision testing solution widely used in the inspection and quality control of video packaging materials. With remarkable accuracy (C: ≤ RSD 0.5%) and sensitivity (0.1 PPM), the analyzer helps manufacturers ensure that the carbon and sulfur content in packaging materials meets stringent industry standards. This analyzer provides fast and reliable results, ensuring that packaging materials are of the highest quality for video products, preventing defects and ensuring product longevity.
Key Features and Benefits
Exceptional Precision and Sensitivity: The QR-9000S provides precise carbon and sulfur analysis with an accuracy of ≤ RSD 0.5% for carbon and ≤ RSD 1.0% for sulfur. Its high sensitivity of 0.1 PPM allows for the detection of even the smallest impurities, ensuring that the packaging materials used in video packaging maintain their integrity.
Fast Analysis Time: With a typical analysis time of 35 seconds, the QR-9000S offers rapid results, making it ideal for high-throughput production lines. Manufacturers can quickly assess the quality of packaging materials, ensuring that any issues are detected and addressed without delays.
Advanced Infrared Detection: The analyzer features a platinum infrared light source and a high-precision pyroelectric infrared detector, offering stable and accurate performance during analysis. This technology ensures the accuracy of results, even in demanding production environments.
Ease of Use and Software Integration: The QR-9000S comes with intuitive software that supports both Chinese and English interfaces. The software allows for easy switching between detection pools and tracks the entire analysis process for real-time adjustments. The analyzer’s automated processes minimize human error and increase operational efficiency.
Durable and Cost-Effective: Built with a high-frequency combustion system and gold-plated analysis cell, the QR-9000S is designed for long-term durability and reliability. Its modular design reduces maintenance costs and ensures stable performance over time.
Applications in Video Packaging Materials Inspection
The QR-9000S High-Frequency Infrared Carbon and Sulfur Analyzer is specifically designed for inspecting packaging materials used in video products, such as DVDs, Blu-rays, and video cassettes. In the packaging industry, carbon and sulfur content can significantly impact the material's strength, durability, and resistance to environmental factors. Packaging materials with high carbon or sulfur content may lead to defects in the final product, including issues with material degradation, sealing problems, or reduced longevity.
By accurately measuring the carbon and sulfur content in packaging materials, the QR-9000S ensures that these materials meet the highest standards of quality and reliability. Whether for raw materials or finished packaging, the analyzer helps ensure that the materials used in video packaging can withstand environmental stressors such as humidity, temperature fluctuations, and physical wear.
Advantages
Improved Product Quality: The QR-9000S helps manufacturers ensure that video packaging materials meet the highest standards, reducing the risk of defects and improving overall product quality.
Faster Testing and Analysis: The analyzer’s fast testing time, typically 35 seconds, ensures that packaging materials are assessed quickly, reducing production delays and increasing throughput.
Reliable Performance: With its advanced infrared detection system, the QR-9000S provides consistent and reliable results, ensuring the accuracy of the data and maintaining the integrity of the inspection process.
Cost-Effective Solution: The analyzer’s durable design, low maintenance requirements, and energy-efficient operation make it a cost-effective choice for video packaging manufacturers looking to improve their quality control processes.
Technical Specifications
Specification Value
Measurement Element C and S
Measurement Range C: 0.000001% – 99.999999% (expandable)
S: 0.000001% – 99.999999% (expandable)
Analytical Precision C: ≤ RSD 0.5%, S: ≤ RSD 1.0%
Sensitivity 0.1 PPM
Analysis Time 25-60s (typically 35s)
Oscillation Frequency 20 MHz
Burning Power 2.5 KVA – 7.5 KVA (adjustable)
Working Environment 10°C – 30°C, 75% relative humidity
Voltage AC220V ± 5%, Frequency: 50Hz ± 2%
Communication USB data exchange technology
Conclusion
The QR-9000S High-Frequency Infrared Carbon and Sulfur Analyzer is an essential tool for the inspection and quality control of video packaging materials. Its precision, speed, and reliability help manufacturers ensure that their packaging materials meet the highest standards of performance and durability. With its advanced infrared detection system, quick analysis time, and user-friendly interface, the QR-9000S is the ideal choice for enhancing the quality control process in video packaging production.
Recommended Products
