Intelligent High Frequency Carbon And Sulfur Analyzer QR-9000S For Accurate Analysis
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Details
| Certifications | ISO, CE | Power Supply | AC 220V/50Hz |
|---|---|---|---|
| Elemental Analysis | Carbon And Sulfur | Detection Method | Infrared Absorption Method |
| Measurement Range | 0.0001% - 100% | Software | Included |
| Analysis Time | Less Than 5 Minutes | Sample Weight | 0.2g - 1g |
| Communication Interface | USB | ||
| Highlight | Intelligent carbon and sulfur analyzer,carbon and sulfur analyzer High Frequency,Accurate Analysis infrared sulfur analyzer |
||
You can tick the products you need and communicate with us in the message board.
| Measurement range | Cω(C): 0.000001%~99.999999% (≤10% or ≥10% expandable to 99.9999%)Sω(S): 0.000001%~99.999999%(≤10% or ≥10% expandable to 99.9999%) | |
|---|---|---|
| Analytical precision | C:≤RSD0.5%. S:RSD≤1.0% | |
| Sensitivity | 0.1PPM | |
| Analysis time | 25-60s (normally 35s) | |
| Analytic error | meet standard: JJG395-2016 (C: ISO9556, S: ISO4935) | |
| Oscillation frequency | 20MHz | |
| Burning power | 2.5KVA—7.5KVA( adjustable) | |
| Working environment | Indoor temperature: 10℃~30℃Relative humidity: 75% | |
| Voltage | AC220V±5%, Frequency:50H±2% |
Product Description
Intelligent High Frequency Infrared Carbon and Sulfur Analyzer QR-9000S
Technical Specifications
| Measurement Elements | Carbon (C) and Sulfur (S) |
| Measurement Range | Cω(C): 0.000001%–99.999999% (≤10% or ≥10% expandable to 99.9999%) Sω(S): 0.000001%–99.999999% (≤10% or ≥10% expandable to 99.9999%) |
| Analytical Precision | C: ≤RSD 0.5% S: RSD ≤1.0% |
| Sensitivity | 0.1 PPM |
| Analysis Time | 25-60 seconds (typically 35s) |
| Analytic Error | Complies with JJG395-2016 standard (C: ISO9556, S: ISO4935) |
| Oscillation Frequency | 20 MHz |
| Burning Power | 2.5 KVA–7.5 KVA (adjustable) |
| Working Environment | Temperature: 10℃–30℃ Relative Humidity: 75% |
| Voltage | AC220V±5%, Frequency: 50H±2% |
Intelligent Features
- Four physical detection pools with automatic switching capability
- VB.net software with Chinese/English language switching
- Full-process signal tracking with automatic adjustment
- Automatic storage of carbon and sulfur release curves for real-time comparison
- Linear data correction for high, medium, and low values
Instrument Characteristics
Infrared Detection System
- Modular design with highly integrated, stable electronic circuits
- Multi-level isolation to eliminate high-frequency interference
- USB data exchange technology for high-speed communication
- Linear integrated module power supply for stable output
- Platinum infrared light source with high efficiency and stable spectral characteristics
- Gold-plated analysis cell with high-precision pyroelectric infrared detector
- Thermally stable motor with long service life
High Frequency Combustion System
- Self-excited directional coupler for consistent power output
- 7.5kvA high-frequency power tubes (actual usage >2.5kvA)
- Ceramic high-power electronic tubes and vacuum capacitors (100A)
- Automatic detection of solenoid valves, lifting cylinders, and high-frequency furnaces
- Automatic obsolescence/overcurrent alarm protection
- High precision flow meters for stable analysis results
- Super microporous "non-clogging" metal filter for complete dust/gas separation
- Pneumatic furnace head automatic cleaning device
Software Features
- Windows operating system
- Custom infrared analysis software with complete functions:
- Channel selection
- Data statistics
- Breakpoint correction
- Results modification
- System diagnostics
- Dynamic data integration (32 samples/second) for enhanced sensitivity and accuracy
- Full-process signal tracking with automatic adjustment
- 20 analysis channels and 100 release curves storage
- Communication with data center or production site reporting
- Integration with computer, printer, and electronic scale
![]()